mutable-instruments/grids

Grids

Mutable Instruments

Topographic drum sequencer — 3-channel trigger generator that derives rhythmic patterns from a 2D map of drum loops learned from electronic music data, with per-channel density control, CV-controllable X/Y map position, and optional Euclidean sequencer mode.691

Capabilities 3

Clock Sourceclock-source
Built-in clock from 40–240 BPM with tap tempo; also accepts external clock at 4, 8, or 24 PPQN.691
Euclidean Sequencereuclidean-sequencer
691
Trigger Sequencertrigger-sequencer
3-channel topographic drum trigger sequencer with X/Y map position, per-channel fill density, and chaos randomization.691

Jacks 12 — 6 in / 6 out

NameSignalVoltageDescription
Inputs (6)
CHAOS CVcv0V to 5VCV input summed with the CHAOS knob. 0V = knob minimum, 5V = knob maximum.691
CLOCKclock0V to 5VExternal clock input. Ignored unless the CLOCK knob is at minimum and tap tempo is reset.691
FILL CVcv0V to 5VCV input summed with the FILL knobs. 0V = knob minimum, 5V = knob maximum.691
MAP X CVcv0V to 5VCV input summed with the MAP X knob. 0V = knob minimum, 5V = knob maximum.691
MAP Y CVcv0V to 5VCV input summed with the MAP Y knob. 0V = knob minimum, 5V = knob maximum.691
RESETtrigger0V to 5VPattern reset input. A rising edge resets the rhythmic pattern to its first step.691
Outputs (6)
ACC 1trigger≤5VAccent output for channel 1. Indicates structurally important steps; compatible with x0x-style modules. +5V, 1ms. Reconfigurable as global ACC, CLK, or RST output.691
ACC 2trigger≤5VAccent output for channel 2. Indicates structurally important steps; compatible with x0x-style modules. +5V, 1ms.691
ACC 3trigger≤5VAccent output for channel 3. Indicates structurally important steps; compatible with x0x-style modules. +5V, 1ms.691
TRIG 1trigger≤5VTrigger output for channel 1 (BD). +5V, 1ms pulses (default; reconfigurable as gate).691
TRIG 2trigger≤5VTrigger output for channel 2 (SD). +5V, 1ms pulses (default; reconfigurable as gate).691
TRIG 3trigger≤5VTrigger output for channel 3 (HH). +5V, 1ms pulses (default; reconfigurable as gate).691

Parameters 8

NameTypeRangeBehavior
CHAOSknobControls amount of random perturbations applied to the three FILL parameters. At high values, rolls/ghost notes are randomly added to the pattern. In swing mode, controls swing amount instead.691
CLOCK Rateknob40BPM – 240BPMControls internal clock rate from 40 to 240 BPM. Fully CCW disables the internal clock and enables external clock input on CLOCK jack.691
FILL 1knobSets note density for channel 1. CCW mutes the channel entirely; CW fills the pattern completely. Added/removed note positions depend on the X/Y backbone.691
FILL 2knobSets note density for channel 2. CCW mutes the channel entirely; CW fills the pattern completely.691
FILL 3knobSets note density for channel 3. CCW mutes the channel entirely; CW fills the pattern completely.691
MAP XknobSpecifies the X coordinate of the rhythm map region, determining the structure/backbone of the rhythm.691
MAP YknobSpecifies the Y coordinate of the rhythm map region, determining the structure/backbone of the rhythm.691
TAP/ResetbuttonActs as tap tempo; flashes on each beat. Tap twice or more to set the tempo — the interval between the two most recent taps defines one beat. Locks the CLOCK knob; tap once to unlock it. Reconfigurable as a reset button via options.691

Firmware history 0 versions

No firmware history recorded.

References 2

  1. [691]
    Mutable Instruments Grids Manualmanual
    verified 2026-05-21
  2. [692]
    Mutable Instruments Grids product pageproduct_page
    verified 2026-05-21